Two items most often raised at VDR surveys are battery capacity and the capsule release device. The battery looks minor but determines whether data survives an incident.

Replacement cycle

Most makers recommend two years, some types are designed for four to five; class and maker instructions prevail. Having the pack on board a month before expiry beats buying on survey day.

Common part numbers

Furuno VR-7000 series uses OEM part 000-179-845-00, see VR-7000 VDR battery; JRC JCY-1000 series uses JCY-1000 VDR battery. They are not interchangeable.

Verification after replacement

Run a power-loss test: cut main supply, confirm recording continues, the beacon works and the system restarts automatically on recovery. Replacing without testing is a common cause of survey failure.

For unit or capsule overhaul, see the spare lists for Furuno VR-7000 VDR and JRC JCY-1900 VDR.

Cannot find the part number?

Send a nameplate photo, old part number or drawing; we reply with availability and lead time within 48 hours.